Inquiry of the product
Electron parts business headquarters
TEL81-3-3270-8853 |
|
MR sensor module
MRM-200
Sample(s) can be ordered here.
Sample Price (Japanese yen) |
1p/lot
|
500p/lot
|
1000p/lot
|
10,000 |
6,000 |
5,400 |
|
Download PDF file (Unready)
Adobe Reader is necessary for the reading
 |
 |

The InSb MR sensor that resistance value changes by the magnetic field, and three optical sensors were made a module. The advanced distinction of U.S. dollers or Eurodollars is possible by using the signal of magnetic sensors and optical sensors. Ask us as for the details. |
Feature
In the module, three infrared sensors (permeation type) and two MR sensores (confrontation type) are placed.
This can be connected to the A/D device such as a microcomputer easily.
The magnetic signal of the bill can be observed easily.
An optical sensor is using the infrared wavelength of the permeation type.
By combining the output of the MR sensor and the infrared sensor, you can do the authenticity judgement of the bill easily.
|
Absolute Maximum Rating (Ta=25C) |
Item |
Symbol |
Standard Value |
Unit |
Excitation,Maximum |
Vamax |
6 |
V |
Operation Environmental Temperature |
TOPG |
+5 to +45(Reccomend +15 to +35) |
℃ |
Electrical Property (Ta=25C) |
Item |
Symbol |
Condition |
min. |
Typ. |
Max. |
Unit |
Supply Current |
- |
4.0V |
- |
- |
55 |
mA |
MR Sensor
(Detection Width) |
W |
6(×2) |
- |
- |
- |
mm |
MR Sensor
(Output Voltage) |
- |
30Hz
100Hz
400Hz |
0.90Vrms *1
1.0Vrms *1
0.90Vrms *1 |
- |
-
|
Vpeak |
MR Sensor
(Noise at no input signal) |
- |
20Hz to 1 kHz |
- |
180 |
20 |
mVp-p |
Optical Sensor
(OPT1 Output Voltage) |
- |
Shade *2 |
- |
1.8±0.3 |
- |
V |
Open |
- |
3.8±0.1 |
- |
Optical Sensor
(OPT2 Output Voltage) |
- |
Shade *2 |
- |
1.8±0.3 |
- |
V |
Open |
- |
3.8±0.1 |
- |
Optical Sensor
(OPT3 Output Voltage) |
- |
Shade *2 |
- |
1.8±0.3 |
- |
V |
Open |
- |
3.8±0.1 |
- |
*1 A magnetic signal is output around about DC2V at 4.0V (power supply voltage). This is the output which it can get by the magnetic field which occurs from the copper wire, when a dedicated device was used in the detection part of the magnetic sensor and the electric power of a sine wave 100mArms was passed through the copper wire of φ1mm.
*2 An exclusive covering seat for the examination is used.. |
Recommended POWER SUPPLY Specifications |
Noise Frequency |
Power Supply Noise |
~5kHz |
1mVp-p max. |
5kHz~ |
2.5mVp-p max. |
# The product specifications and the appearance are possibility of changing without notice.

|