Inquiry of the product
Electron parts business headquarters
TEL81-3-3270-8853 |
|
MR Sensor
MRS-09S
Sample(s) can be ordered here.
Sample Price (Japanese yen) |
1p/lot
|
500p/lot
|
1000p/lot
|
6,000 |
3,800 |
3,300 |
|
|
 |

This sensor is made from InSb magnetic resistance. That resistance value changes by the magnetic field and the permanent magnet which gives this sensor magnetic bias. When a magnetic substance approaches the detection side, an output signal can be received because the magnetic flux density which affects the magnetic resistance changes and the resistance value of this senser is changed. Because it is 2 circuit built-in type, it is the most suitable for the use such as a position transducer of the servomotor for the magnetic encoder. |
Feature
Rotating direction can be detected for 2 circuit building in.
A magnetic resistance element is an InSb mono-crystal. That sensitivity and the ratio of S/N are high.
It can be detected even if detected material doesn't stick to the detection side.
Output doesn't depend on the movement speed of the magnetic body, and it can detect a stationary body.
A detection part is pure resistance, and hardly catches guidance noise.
It is the miniature metal case package which can use even the limited space
|
Absolute Maximum Rating (Ta=25C) |
Item |
Symbol |
Standard Value |
Unit |
Excitation,Maximum |
Vamax |
6.3 |
V |
Allowable Loss |
PD |
100 |
mW |
Operation Environmental Temperature |
PD |
-10 ~ +80 |
℃ |
Operation Environmental Humidity |
|
-0 ~ +98 |
%RH |
Preserved Environmental Temperature |
Tstg |
-40 ~ +120 |
℃ |
Electrical Property (Ta=25C) |
Item |
Symbol |
Condition |
min. |
Typ. |
Max. |
Unit |
Input resistance |
R |
*1 Ic≦1mA
|
200
|
- |
2000
|
Ω
|
Offset Voltage |
Voa
Vob
|
*1 |
(Vin/2)×(1±0.13)
|
V
|
Output voltage |
VA
VB
|
*2
|
0.53
|
-
|
0.90
|
Vp-p
|
Output Voltage Ratio |
VA/VB |
*2
|
0.90
|
-
|
1.10
|
|
Output Voltage Phase |
α
|
*2 VA-VB間
|
90 ± 5
|
deg
|
Isolation Resistance |
DC 500V |
100 |
- |
- |
MΩ |
AC voltage resistant |
AC 500V
1min.
|
It is necessary that there is no wrong point. |
|
*1Condition of measurement
When a gap is ∞ from the detected thing.Input voltage : less than 5.25V
(at the time of the neutral voltage measurement)
|
*2 Condition of measurement
Input voltage : 5.00±0.01V
Gap: 0.15±0.02mm
Revolution : 1500±100r.p.m
Designated gear :module 0.4
Tooth form:involute ordinariness tooth
Pressure angle:20°
Number of teeth:256
Tooth width:9mm
Quality of material:S45C
Precision:the JIS the 4th rank
|
# The product specifications and the appearance are possibility of changing without notice.

|